4.9 Test Run with Load Connected
Start-Up Programming
& Operation
4
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual 121
4.9 Test Run with Load Connected
Test Run with the Load Connected
After performing a no-load test run, connect the motor and proceed to run the motor and load together.
Notes on Connected Machinery
Clear the area around the motor.
The motor should come to a complete stop without problems.
Connect the load and machinery to the motor.
Fasten all installation screws properly. Check that the motor and connected machinery are held in place.
Confirm that the Fast Stop circuit or mechanical safety measures operate correctly.
Be ready to press the STOP button in case of emergency.
Checklist Before Operation
The motor should rotate in the proper direction.
The motor should accelerate and decelerate smoothly.
Operating the Motor under Loaded Conditions
Test run the application similarly to the no-load test procedure when connecting the machinery to the motor.
Watch monitor parameter U1-03 during operation to ensure there is no overcurrent.
If the application permits running the load in the reverse direction, try changing motor direction and the frequency
reference while watching for abnormal motor oscillation or vibration.
Correct any problems that occur with hunting, oscillation, or other control-related issues.
SIEP_C710616_35.book 121 ペー 2015年11月30日 月曜日 午後2時2分

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA E1000 and is the answer not in the manual?

YASKAWA E1000 Specifications

General IconGeneral
BrandYASKAWA
ModelE1000
CategoryController
LanguageEnglish

Related product manuals