7.2 Inspection
Periodic Inspection &
Maintenance
7
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual 299
7.2 Inspection
Power electronics have limited life and may exhibit changes in characteristics or performance deterioration after years of
use under normal conditions. To help avoid such problems, it is important to perform preventive maintenance and
periodic inspection on the drive.
Drives contain a variety of power electronics such as power transistors, semiconductors, capacitors, resistors, fans, and
relays. The electronics in the drive serve a critical role in maintaining proper motor control.
Follow the inspection lists provided in this chapter as a part of a regular maintenance program.
Note: The drive will require more frequent inspection if it is placed in harsh environments, such as:
High ambient temperatures
Frequent starting and stopping
Fluctuations in the AC supply or load
Excessive vibrations or shock loading
Dust, metal dust, salt, sulfuric acid, chlorine atmospheres
Poor storage conditions.
Perform the first equipment inspection one to two years after installation.
Recommended Daily Inspection
Table 7.1 outlines the recommended daily inspection for Yaskawa drives. Check the following items on a daily basis to
avoid premature deterioration in performance or product failure. Copy this checklist and mark the “Checked” column
after each inspection.
Table 7.1 General Recommended Daily Inspection Checklist
Inspection Category Inspection Points Corrective Action Checked
Motor Inspect for abnormal oscillation or noise coming from the motor.
Check the load coupling.
Measure motor vibration.
Tighten all loose components.
Cooling
Inspect for abnormal heat generated from the drive or motor and
visible discoloration.
Check for excessive load.
Loose connections
Check for dirty heatsink or motor.
Ambient temperature
Inspect drive cooling fan and circulation fan operation.
Check for clogged or dirty fan.
Check fan operation drive parameter.
Inspect drive airfilter. Check for the dirty airfilter.
Environment
Verify the drive environment complies with the specifications listed
in Installation Environment on page 44.
Eliminate the source of contaminants or correct poor
environment.
Load
The drive output current should not be higher than the motor or drive
rating for an extended period of time.
Check for excessive load.
Check the motor parameter settings of the drive.
Power Supply Voltage Check main power supply and control voltages.
Correct the voltage or power supply to within nameplate
specifications.
Verify all main circuit phases.
SIEP_C710616_35.book 299 ペー 2015年11月30日 月曜日 午後2時2分

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA E1000 and is the answer not in the manual?

YASKAWA E1000 Specifications

General IconGeneral
BrandYASKAWA
ModelE1000
CategoryController
LanguageEnglish

Related product manuals