A.2 Three-Phase 400 V Class Drives
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual 351
A.2 Three-Phase 400 V Class Drives
Table A.2 Power Ratings (Three-Phase 400 V Class)
Item Specification
CIMR-E4A 0002 0004 0005 0007 0009 0011 0018 0023 0031 0038 0044 0058 0072 0088 0103
Maximum Applicable Motor Capacity (kW) <1>
0.75 1.5 2.2 3 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55
Input
Input Current (A) <2> 2.1 4.3 5.9 8.1 9.4 14 20 24 38 44 52 58 71 86 105
Rated Voltage
Rated Frequency
Three-phase 380 to 480 Vac 50/60 Hz/510 to 680 Vdc
<3>
Allowable Voltage Fluctuation -15 to 10%
Allowable Frequency Fluctuation ±5%
Input Power (kVA)
2.3 4.3 6.1 8.1 10.0 14.5 19.4 28.4 37.5 46.6 54.9 53.0 64.9 78.6 96.0
Output
Rated Output Capacity (kVA) <4> 1.6 3.1 4.1 5.3 6.7 8.5 13.3 17.5 24 29 34 44 55 67 78
Rated Output Current (A) <5> 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23 31 38 44 58 72 88 103
Overload Tolerance
120% of rated output current for 60 s.
Note: Derating may be required for applications that start and stop frequently.
Carrier Frequency
1 to 15 kHz <6>
Maximum Output Voltage (V)
Three-phase 380 to 480 V (proportional to input voltage)
Maximum Output Frequency (Hz)
200 Hz <6>
Item
<1> The motor capacity (kW) refers to a Yaskawa 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor rated current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring
conditions, and power supply impedance.
<3> DC is not available for UL/CE standards.
<4> Rated motor capacity is calculated with a rated output voltage of 440 V.
<5> Current derating is required in order to raise the carrier frequency.
<6> User adjustable
<7> Maximum output voltage is 0.95 × [input voltage].
Specification
CIMR-E4A 0139 0165 0208 0250 0296 0362 0414 0515 0675 0930 1200
Maximum Applicable Motor Capacity (kW) <1>
75 90 110 132 160 185 220 250 355 500 630
Input
Input Current (A) <2> 142 170 207 248 300 346 410 465 657 922 1158
Rated Voltage
Rated Frequency
Three-phase 380 to 480 Vac 50/60 Hz/510 to 680 Vdc
<3>
Allowable Voltage Fluctuation -15 to 10%
Allowable Frequency Fluctuation ±5%
Input Power (kVA)
129.9 155.5 189 227 274 316 375 416 601 843 1059
Output
Rated Output Capacity (kVA) <4> 106 126 159 191 226 276 316 392 514 709 915
Rated Output Current (A) <5> 139 165 208 250 296 362 414 515 675 930 1200
Overload Tolerance
120% of rated output current for 60 s
Note: Derating may be required for applications that start and stop frequently.
Carrier Frequency
1 to 10 kHz <6> 1 to 5 kHz <6>
Maximum Output Voltage (V)
Three-phase 380 to 480 V (proportional to input voltage) <7>
Maximum Output Frequency (Hz)
200 Hz <6> 150 Hz <6>
SIEP_C710616_35.book 351 ページ 2015年11月30日 月曜日 午後2時2分