Gen II User Manual
7-42 – Main Rotor Track & Balance Chapter 7 Revision 3.00, Apr 2020
Max ICF Update: This field is used to restrict the learning criteria for track adjustments. The
example uses 50%. With 50% selected, any movement over 50% of the expected
result for a given adjustment, and the analyzer will not update the ICF. Using the
keypad, enter the desired parameter to be placed in the setup.
No Adjustment Bld/Pos.: This field is used to designate a main rotor blade as a “no adjustment
blade.” This feature is used when the OEM suggests that no adjustments be applied
to a particular blade during a track and balance job. An optimized solution is
provided by the analyzer that requires no adjustments to the designated “No
Adjustment Blade”.
Press [OK] to save the setup.
Revision History
3/10/2015 1.01: Updated broken reference links and added revision history table. Moved Analyzer Chart Forms
section from 7.1 to 7.7.
Berlin
11/9/2015 1.02: Added text about the Polar Chart view. Main Polar view explanation in Chapter 24. Lucas
2/12/2016 2.00: Major rewrite generalizing the manual to cover both the Viper II and Cobra II. This chapter was
updated with screenshots and corrections to minor typographical errors.
East
4/30/2020 3.00 Major revision including updated screen shots to reflect software updates and minor verbiage changes. Underwood