Gen II User Manual
16-10 – Monitor Spectrum Chapter 16 Revision 2.10, Apr 2020
16.1.3.3.3. “Current” – Displays the current values for each channel configured.
16.1.3.3.4. “MxChan(x)” – Displays the maximum values recorded for the indicated channel.
16.1.3.3.5. “Units” – Displays the unit of measure selected in paragraph 16.1.1.9 above for each
sensor channel configured.
16.1.3.3.6. “% Speed” (Viper II only) – Displays the speed in percent for each tach configured
ONLY if a 100% speed value was in entered in paragraph 16.1.1.19 above. Otherwise,
these fields will be blank.
16.1.3.4. – Function Key Options when viewing Overall
16.1.3.4.1. Pressing the [F1] “Maximum” key changes the function key menu options to the channel
select sub-menu. This allows the user to view all values in relation to the maximum
values for the selected channel. For example, pressing [F2] will display the readings of all
channels when Channel B reached its maximum value as shown below. The default
selection is Channel A and the heading over the third column is reads “MxChanA”. This
will change to display the selected channel as shown in the screenshot below.
16.1.3.4.2. [F2] “Pause” – will pause the acquisition process and change to “Resume” when pressed.
Pressing the key a second time will resume the data acquisition process without resetting
any values.
16.1.3.4.3. [F4] “Spectra” – When pressed, the display will change to show the spectra plot as shown
in paragraph 16.1.3.1 above.
16.1.3.4.4. [F5] “Restart” – will reset all of the recorded values to zero and begin the sample count
again.