7 — ONT equipment layout
7-38 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA
Note
(1)
This interface is not supported on all ONT units. See the business ONT UDS and the SOHO outdoor
ONT UDS for details.
O-821G-D and O-820G-D connections
Figure 7-29 shows the O-821G-D small office home office (SOHO) outdoor ONT
physical connections.
Figure 7-29 Connectors on an O-821G-D SOHO outdoor ONT
Power and alarm
connections
Terminals are provided to connect an external –48 V dc UPS to the business
ONT with support for battery alarm connections.
RF video
connection
(1)
This connection is provided through the F-type connector for CATV service.
Each business ONT supports one RF video connection. Standard 75 Ω coaxial
cable can be used, including: RG59, RG6, or Series 7 coaxial cable.
Connection Function
(2 of 2)
TELCO ACCESS
TRTRTRTR TRTRTRTR TRTRTRTR TRTRTRTR TRTRTRTR TRTRTRTR
INPUT RATING: DC
45V 55V 1.0A
THIS DEVICE IS INTEDED TO BE
ATTACHED TO A RECEIVER THAT IS
NOT USED TO RECEIVE OVER-THE0AIR
BROADCAST SIGNALS. CONNECTION OF
THIS DEVICE IN ANY OTHER FASHION
MAY CAUSE HARMFUL INTERFERENCE
TO RADIO COMMUNICATION AND IS
IN VIOLATION OF THE FCC RULES,
PART 15.
VIDEO
PWR
BLK
LINE
1
BTRY
FAIL
VIDEO
DATA
NTWK
MGMT
INTF
POTS
1
MODE LINK
ETHERNET
MODE LINK
ETHERNET
2
LINE
2
LINE
3
LINE
4
LINE
5
LINE
6
LINE
7
LINE
8
TELCO ACCESS
Power and alarm
connector
Auxillary Power
Terminal Block
Ethernet 1
(RJ-45)
Ethernet 1
IDC connector
Ethernet 2
(RJ-45)
Ethernet 2
IDC connector
GND
OptiTap
fiber
connector
(Optional)
Class 1 power and
fiber conduit box
POTS IDC
connectors (5 to 8
POTS IDC
connectors (1 to 4
F-type
coaxial
1888
POTS ports
(RJ-11)
TRTRTRTR TRTRTRTR