10 — ONT technical specifications
10-30 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA
Table 10-40 MoCA SOHO outdoor ONT transmit output power variance
Business ONT
B-xxxx-x ONTs require 48 V DC input power supplies. See the appropriate ONT
data sheet for specific UPS support. Alcatel-Lucent recommends the use of a listed
DC power supply with LPS or Class 2 outputs, suitably approved and rated for the
application. Outputs at SELV/LPS levels rated for 48 V dc, 3.124 A are required. The
Alcatel-Lucent approved UPSs for the business ONT are the:
Table 10-41 lists the measured power consumption values for the business ONT.
Table 10-41 Business ONT power consumption
Note
(1)
Idle power consumption is calculated with all eight POTS lines on-hook, no Ethernet connected,
and RF video disabled. Power consumption for the active state is calculated for maximum usage
with all eight POTS lines off-hook, Ethernet ports active, RF video enabled, and the DS1/E1 ports
active.
LP MDU ONT
O-xxxxxx-x LP MDUs require -48 V DC input power supplies. See the appropriate
ONT data sheet for specific UPS support
Item TL1 value (dBm) Expected output
power (dBm)
Description
MoCA Tx power
variance
-26 and lower -26
-23, -24, -25 -23
-20, -21, -22 -20
-17, -18, -19 -17
-14, -15, -16 -14
-11, -12, -13 -11
-8, -9, -10 -8
-5, -6, -7 -5
-2, -3, -4 -2
0, -1 0
Power consumption
(1)
Idle Active
21 W 24 W