38 — CyberPower CyberShield CS 36 PSU/BBU unit data sheet
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 38-7
3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual
The BBU has the following output specifications when powered by the PSU:
• output voltages: 13.1 to 14.5 V dc normally
• output current: 2A continuous, 3A maximum
• output power capacity: 36 W
• efficiency: > 80% at full load by specification
The BBU has the following output specifications when using the backup battery or
auxiliary power:
• output voltages for battery backup: 10.5 to 20 V dc while discharging
• output voltages for auxiliary power: 12.5 to 20 V dc (1.3 mm coax power jack)
• efficiency: > 80% at full load by specification
Environmental
Table 38-7 lists the environmental conditions for the CyberShield CS 36 PSU/BBU.
Table 38-7 CyberShield CS 36 PSU/BBU environmental conditions
Note — The backup battery supports ONT operations for a minimum
of 8 h with the loading profile defined in GR-1089.
Temperature range and humidity Altitude range
Operating:
–4°F to 115°F (–20°C to 50°C) plus solar loading
Operating humidity:
0% to 95% non-condensing within enclosure
Operating altitude:
0 to 10 000 ft (0 to 3 000 m)
Storage:
–40°F to 115°F (–40°C to 50°C)
Humidity:
0% to 95% non-condensing within enclosure
Storage altitude:
0 to 10 000 ft (0 to 3 000 m)