38 — CyberPower CyberShield CS 36 PSU/BBU unit data sheet
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 38-5
3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual
38.6 Connections
The voltage output connector at the BBU is a removable, 9-position IDC connector.
A 9-position Phoenix IDC connector is also used at the ONT.
The PSU has the following:
• input connector: NEMA 6-15 plug
• cord length: 8.0 ft (2.44 m)
• output connector: Phoenix QC 0.5/2-ST-3.81 LC RD/BK IDC connector
Table 38-5 describes the PSU output pinouts.
Table 38-5 PSU output pinouts
The BBU has the following input/output connectors:
• input connector: Phoenix QC 0.5/2-ST-3.81 LC RD/BK IDC connector
• cord length: 8.0 ft (2.44 m)
• output connector: Phoenix QC 1.5/7-ST-5.00 COD FTTH IDC connector
Table 38-6 describes the BBU output pinouts.
Table 38-6 BBU output pinouts
MISSING BATTERY 8 The battery-missing alarm indicates that no battery is
detected or battery is incorrectly connected.
LOW BATTERY 9 The low-battery alarm indicates that the battery charger
has fallen below 45% capacity when operating from the
battery.
Signal Pin Description
(2 of 2)
Pin number Signal Wire color
1 +48 V (V dc) Red (RED)
2 –48 V (Vo dc) Black (BLK)
Wire color Pin number Signal
Red (RED) 1 48 V in +
Black (BLK) 2 48 V in –
Red (RED) 3 12 V out +
(1 of 2)