EasyManua.ls Logo

Alcatel-Lucent 7342 - Connections

Alcatel-Lucent 7342
448 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38 — CyberPower CyberShield CS 36 PSU/BBU unit data sheet
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 38-5
3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual
38.6 Connections
The voltage output connector at the BBU is a removable, 9-position IDC connector.
A 9-position Phoenix IDC connector is also used at the ONT.
The PSU has the following:
input connector: NEMA 6-15 plug
cord length: 8.0 ft (2.44 m)
output connector: Phoenix QC 0.5/2-ST-3.81 LC RD/BK IDC connector
Table 38-5 describes the PSU output pinouts.
Table 38-5 PSU output pinouts
The BBU has the following input/output connectors:
input connector: Phoenix QC 0.5/2-ST-3.81 LC RD/BK IDC connector
cord length: 8.0 ft (2.44 m)
output connector: Phoenix QC 1.5/7-ST-5.00 COD FTTH IDC connector
Table 38-6 describes the BBU output pinouts.
Table 38-6 BBU output pinouts
MISSING BATTERY 8 The battery-missing alarm indicates that no battery is
detected or battery is incorrectly connected.
LOW BATTERY 9 The low-battery alarm indicates that the battery charger
has fallen below 45% capacity when operating from the
battery.
Signal Pin Description
(2 of 2)
Pin number Signal Wire color
1 +48 V (V dc) Red (RED)
2 –48 V (Vo dc) Black (BLK)
Wire color Pin number Signal
Red (RED) 1 48 V in +
Black (BLK) 2 48 V in –
Red (RED) 3 12 V out +
(1 of 2)