10 — ONT technical specifications
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-21
3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual
The environmental specifications of the SWRD:
The operating temperature range is –40°F (-40°C) to 140°F (60°C) and to the
equivalent of +41°C with solar loading
The operating relative humidity range is 5% to 95%, non-condensing.
The operating altitude range is 200 ft (61 m) below mean sea level to 13 000 ft
(3962 m) above mean sea level.
The operating altitude range is 200 ft (61 m) below mean sea level to 13 000 ft
(3962 m) above mean sea level.
operating temperature may vary by 16.6°C (2°F) per minute, to the maximum and
minimum ranges
The physical specifications of the SWRD:
housing dimensions 6.78 in wide by 1.29 in deep by 5.77 in tall (17.45 cm by 3.38
cm by 14.66 cm)
weight of 1.5 lbs (0.68 kg)
10.10 Alloptic MicroNode 190 Return Path Transmitter interface
specifications
The Alloptic MicroNode 190 Return Path Transmitter (RPT) used with the
O-211M-R outdoor ONT meets the following compliance and safety standards:
TUV listed
CE mark certified
EMC emissions (U.S. and Canada) FCC part 15, class B
21 CFR 1040.10 and 1040.11
The power specifications of the Alloptic MicroNode 190 RPT are as follows:
input voltage range 10 to 16 V DC (12 V DC nominal)
maximum power consumption of 1watt
The environmental specifications of the Alloptic MicroNode 190 RPT:
The operating temperature range is –40°F (-40°C) to 149°F (65°C)
The operating relative humidity range is 5% to 95%, non-condensing.
The operating altitude range is 200 ft (61 m) below mean sea level to 13 000 ft
(3962 m) above mean sea level.
The operating altitude range is 200 ft (61 m) below mean sea level to 13 000 ft
(3962 m) above mean sea level.
operating temperature may vary by 16.6°C (2°F) per minute, to the maximum and
minimum ranges
The physical specifications of the Alloptic MicroNode 190 RPT:
0.85 in high by 4.9 in wide by 3.7 in deep (2.2 cm by 12.4 cm by 9.4 cm)
weight of MNTH191 (ANSI standards) is 0.43 lbs (0.2 kg)
weight of MNTH192 (ETSI standards) is 0.21 lbs (0.1 kg)