EasyManua.ls Logo

Alcatel-Lucent 7342 - Outdoor ONT (O-420 E-B)

Alcatel-Lucent 7342
448 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 — ONT technical specifications
10-24 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA
Table 10-26 Typical outdoor ONT power consumption, excluding SOHO
Notes
(1)
Power consumption for the O-211M-R ONT is slightly higher than other outdoor ONTs since the
Alloptic MicroNode 190 Return Path Transmitter included in the ONT enclosure has a maximum
power consumption of 1 watt and power input voltage of 10 to 16 V dc (12 V dc nominal).
(2)
With all service interfaces active (in use) and the ONT fully configured.
(3)
With all service interfaces active (in use).
(4)
No service interfaces active.
Table 10-27 provides the transmit output power variance for MoCA ONTs. These
variances assume no board implementation loss or impedance mismatches.
Table 10-27 MoCA outdoor ONT transmit output power variance
Outdoor ONT (O-420E-B)
Table 10-28 provides the power consumption specifications for the O-420E-B
outdoor ONT.
Power consumption
(1)
Power consumption specification
Peak power consumption
(2)
Not exceeding 9 W
Typical power consumption
(3)
Not exceeding 6 W
Power consumption idle
(4)
Not exceeding 4.5 W
Item TL1 value (dBm) Expected output
power (dBm)
Description
MoCA Tx power
variance
-26 and lower -26
-23, -24, -25 -23
-20, -21, -22 -20
-17, -18, -19 -17
-14, -15, -16 -14
-11, -12, -13 -11
-8, -9, -10 -8
-5, -6, -7 -5
-2, -3, -4 -2
0, -1 0

Table of Contents