10 — ONT technical specifications
10-8 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA
Table 10-15 Business and SOHO ONT physical specifications
10.3 Environmental requirements
The following sections describe temperature and humidity ranges, and installation
considerations for rack mounted ONTs.
Temperature and humidity range
Table 10-16 lists the environmental requirements for the ONTs.
Table 10-16 ONT environmental requirements
Dimension Specification
Height 16.29 in. (41.37 cm)
Width 14.39 in. (36.55 cm)
Depth (not including fiber storage tray) 5.95 in. (15.11 cm)
Weight (within ± 0.5 lb (0.23 kg) 11 lb (4.99 kg)
ONT type
Mounting method Temperature range and humidity Altitude
Indoor 10/100BASE-T Ethernet ONTs (I-220E-A, I-221E-A, I-020E-B, and I-020E-H)
Desk or wall
mounted
Operating:
32°F to 104°F (0°C to 40°C) ambient temperature
5% to 85% relative humidity, non-condensing
Maximum operating altitude 10 000
ft (3048 m) above sea level
Storage:
–40°F to 158°F (–40°C to 70°C)
5% to 95% relative humidly, non-condensing
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
Indoor 10/100/1000BASE-T Gigabit Ethernet ONTs (I-240G-A, I-241G-A, I-020G-F, I-020G-G, and I-040G-A)
Desk or wall
mounted
Operating:
32°F to 104°F (0°C to 40°C) ambient temperature
5% to 85% relative humidity, non-condensing
The maximum rate of temperature change is 32.9°F
(0.5°C) per hour
Maximum operating altitude is 10 000
ft (3048 m) above mean sea level
Storage:
-13°F to 133°F (-25°C to 55°C)
5% to 93% relative humidity, non-condensing
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
Indoor MoCA ONTs (I-211M-D, I-211M-E, and I-211M-G)
Wall mounted or
in-wall in a
pre-constructed
telecommunications
cabinet
Operating:
-4°F to 122°F (-20°C to 50°C)
5% to 95% humidity range, non-condensing
5% to 85% humidity range, non-condensing (I-211M-E
only)
Maximum operating altitude is 10 000
ft (3048 m) above mean sea level
(1 of 3)

Table of Contents