10 — ONT technical specifications
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-9
3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual
Storage:
–4°F to 122°F (–20°C to 50°C)
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
Outdoor 10/100BASE-T Ethernet ONTs (O-211E-B, O-210E-B, O-420E-B, and O-421E-B)
Wall mounted with
or without fiber
storage
compartment
Operating:
–40°F to 115°F (–40°C to 46°C) with solar loading
(1)
(2)
–40°F to 140°F (–40°C to 60°C) without solar loading
5% to 95% relative humidity, non-condensing
Maximum operating altitude 10 000
ft (3048 m) above mean sea level
Storage:
–40°F to 158°F (–40°C to 70°C)
5% to 95% relative humidly, non-condensing
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
Outdoor SOHO ONTs (O-820G-D, O-821G-D, and O-821M-E)
Wall mounted with
or without fiber
storage
compartment
Operating:
–40°F to 115°F (–40°C to 46°C) with solar loading
(1)
(2)
–40°F to 140°F (–40°C to 60°C) without solar loading
5% to 95% relative humidity, non-condensing
Maximum operating altitude 10 000
ft (3048 m) above mean sea level
Storage:
–40°F to 158°F (–40°C to 70°C)
5% to 95% relative humidly, non-condensing
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
Outdoor MoCA ONTs (O-211M-C, O-211M-E, O-211M-G, and O-211M-R)
Wall mounted with
or without fiber
storage
compartment
Operating:
–40°F to 115°F (–40°C to 46°C) with solar loading
(1)
(2)
–40°F to 140°F (–40°C to 60°C) without solar loading
For O-211M-R ONTs:
–40°F to 122°F (–40°C to 50°C) without solar loading
5% to 95% relative humidity, non-condensing
Maximum operating altitude 10 000
ft (3048 m) above mean sea level
Storage:
–40°F to 158°F (–40°C to 70°C)
5% to 95% relative humidly, non-condensing
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
Outdoor LP MDU ONTs (O-24121G-A, O-24120G-A, O-24121V-A, and O-24120V-A)
Rack, on wall, or
enclosure
Operating:
single unit installed in a rack indoors is -40°F to 131°F
(-40°C to 55°C)
single unit installed in an enclosure outdoors is –40°F to
114.8°F (–40°C to 46°C) with solar loading
(2)
10% to 95% relative humidity, non-condensing
The maximum rate of temperature change is 91°F (33°C)
The heat dissipation for O-24121V-A and O-24120V-A
ONTs:
average = ~90 W
maximum = ~115 W
Maximum operating altitude is 13 000
ft (3962 m)
Minimum operating altitude is 200 ft
(61 m) below mean sea level
Storage:
–40°F to 158°F (–40°C to 70°C)
10% to 95% relative humidly, non-condensing
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
ONT type
Mounting method Temperature range and humidity Altitude
(2 of 3)