10 — ONT technical specifications
10-10 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA
Notes
(1)
The maximum solar load is 1120 W/m
2
.
(2)
Solar loading per GR-950.
Outdoor MDU ONT (O-00240V-A)
Rack, on wall, or
enclosure
Operating:
single unit installed in a rack indoors is 32°F to 122°F
(0°C to 50°C)
single unit installed in an enclosure outdoors is –40°F to
149°F (–40°C to 65°C) with solar loading
(2)
10% to 95% relative humidity, non-condensing
The maximum rate of temperature change is 91°F (33°C)
Maximum operating altitude is 13 000
ft (3962 m) above mean sea level
Minimum operating altitude is 200 ft
(61 m) below mean sea level
Storage:
–13°F to 158°F (–25°C to 70°C)
10% to 95% relative humidly, non-condensing
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
Modular ONT (M-300-A with S-840V-A plug-in unit)
Rack or wall Operating:
–40°F to 115°F (–40°C to 46°C) with solar loading
(1)
–40°F to 140°F (–40°C to 60°C) without solar loading
5% to 95% relative humidity, non-condensing
Environmentally hardened for external installation.
Withstands rain, but not water submersion.
Plug-in unit is hot-swappable.
Maximum operating altitude 10 000
ft (3048 m) above mean sea level
Storage:
–40°F to 158°F (–40°C to 70°C)
5% to 95% relative humidly, non-condensing
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
Business ONTs (B-8102-A and B-8112-A)
Wall mounted with
or without fiber
storage
compartment
Operating:
–40°F to 115°F (–40°C to 46°C) with solar loading
(1)
–40°F to 140°F (–40°C to 60°C) without solar loading
5% to 95% relative humidity, non-condensing
Maximum operating altitude 10 000
ft (3048 m) above mean sea level
–40°F to 158°F (–40°C to 70°C)
5% to 95% relative humidly, non-condensing
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
ONT type
Mounting method Temperature range and humidity Altitude
(3 of 3)