36 — APC UPS cable assembly with beeper unit data sheet
36-2 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA
36.1 Identification
Table 36-1 provides identification information about the APC UPS cable assembly
with beeper unit.
Table 36-1 Identification of cable beeper assembly
36.2 Features and application notes
The APC UPS cable assembly with beeper provides:
a local power connection from the PowerShield to the subscriber equipment
fast and simple connections reducing installation time
audible beeper assembly for alarms
alarm disable push button that silences the Battery Missing alarm
maximum voltage of 30 V
maximum current of 5 mA
36.3 General description
The cable assembly with beeper as shown in Figure 36-1 is optional. The beeper
assembly attaches to the UPS and has an audible beeper, which sounds when an
alarm is detected. See Table 36-2 for a description of the alarms and their associated
beeps. The beeper also has an alarm disable function for the Battery Missing alarm
that is activated when the alarm disable push button, as shown in Figure 36-2, is
pushed. Its status is acknowledged only when the system has flagged a REPLACE
BATT signal. When acknowledged, the alarm disable function silences the
REPLACE BATT beep sound for 24 h. If the battery has not been replaced after 24
h, the REPLACE BATT beep sound resumes.
Figure 36-1 APC cable assembly with beeper
Part number Description
3EM 11078 AC Cable beeper assembly
1834
1