42 — FlexNet FMPS-150W UPS unit data sheet
42-2 July 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 01 3FE 51892 AAAA TCZZA
42.1 Identification
Table 42-1 provides identification information about the FlexNet FMPS-150W UPS
from Alpha Technologies, Inc. that is used with the small office home office (SOHO)
ONT, business ONT, and LP multi dwelling unit (MDU) outdoor ONT.
Table 42-1 Identification of the FlexNet FMPS-150W UPS
42.2 Features and application notes
The FlexNet FMPS-150W UPS provides:
48 V dc to 58 V dc output when operating on ac power, or 42 V dc to 58 V dc
when using batteries
simple power connections from the + dc lead on the Alpha FMPS to the + input
terminal on the ONT or MDU, and from the – dc lead on the Alpha FMPS to the
– input terminal on the ONT or MDU
150 W output using universal input voltage range of 90 V ac to 320 V ac input
power, 45 Hz to 66 Hz
support for two strings of four 7.2 Ah valve regulated lead acid (VRLA) batteries
provide up to 8 h of backup battery power, depending upon conditions
battery diagnostics, self-testing, and communication capability by alarm output to
the service provider network using the customer premises electronics
surge protection compliant to ANSI/IEEE Std. C62.41 to Category A, B, or C
requirements, using a ring wave or combination waveform at a level of 6 kV
CSA C22.2 No. 60950-1/UL 60950-1 1st Edition, EN 60950-1:2001
42.3 General description
The FlexNet FMPS-150W UPS can be mounted inside the customer’s premises. It
powers the SOHO, business ONT, and LP MDU and provides up to 8 h of backup
power for lifeline POTS services, depending on environmental conditions and load.
The UPS converts 90 V ac to 320 V ac input (45/66 Hz autosensing) to 150 W
continuous output of 48 V dc to 58 V dc. You can install up to two FMPS-150W UPS
units on a single dedicated 15 A circuit.
Part Number Description
1AF 14373 AB FlexNet FMPS-150W UPS with heater. Has
customer specific logo.
1AF 14373 AC FlexNet FMPS-150W UPS without heater.
1AF 14373 AD FlexNet FMPS-150W UPS with heater.
See the 7342 ISAM FTTU ONT Planning and
Ordering Guide
Batteries for the FlexNet FMPS-150W UPS.

Table of Contents