40 — Delta OPSU/BBU unit data sheet
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 40-9
3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual
Environmental
The runtime specifications at 25°C while operating from the battery are defined in
Table 40-7.
Table 40-7 Constant power runtime
The operating conditions are:
temperature range: –4 ° to 115 °F (–20° to 46°C)
relative humidity (non-condensing) within enclosure: 0% to 95%
Constant power 6 W 8 W 10 W
Pre-emergency reserve 9 h 16 min 6 h 34 min 5 h 32 min
Emergency reserve 3 h 5 min 2 h 22 min 1 h 26 min
Total time 12 h 21 min 8 h 59 min 6 h 58 min