10 — ONT technical specifications
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-27
3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual
Table 10-34 Power consumption specifications (I-220E-A and I-221E-A)
Indoor ONT (in-wall MoCA)
Table 10-35 provides the power consumption specifications for the in-wall MoCA
indoor ONT.
Table 10-35 Power consumption specifications (in-wall MoCA indoor ONT)
Power connection inputs are provided using a terminal barrier strip. Battery alarm
inputs are provided using an IDC connector.
The technical specifications for the in-wall MoCA indoor ONT power supply are:
• locally powered
• compatible with various UPS assemblies
• input: 120 V ac
• output: 12 V dc, low voltage
• battery backup (not supplied): up to 8 h
• commercially sealed lead acid battery
• visual battery status indicator for power
• NRTL listed
• battery status monitored
• in-wall MoCA indoor ONT input voltage range: 9.5 to 18 V
• current limit: 2.5 A fuse within the in-wall MoCA indoor ONT
Indoor ONT (I-211M-D)
Table 10-36 provides the power consumption specifications for the I-211M-D ONT.
Power consumption Specifications
Maximum power consumption Not exceeding 7.6 W with all services active
(2 POTS off-hook, RF video enabled, and 2 Ethernet for data
operational)
Minimum power consumption Not exceeding 4.5 W with all services idle
(2 POTS lines on-hook, no RF video, or Ethernet ports
provisioned.)
Power consumption Specifications
Peak power consumption Not exceeding 15.0 W with all services active (2 POTS
on-hook and 1 Ethernet for data operational)
Power consumption with all service
interfaces idle
Not exceeding 9.0 W