10 — ONT technical specifications
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 10-25
3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual
Table 10-28 Power consumption specifications (O-420E-B)
Outdoor ONT (O-210E-B)
Table 10-29 provides the power consumption specifications for the O-210E-B
outdoor ONT.
Table 10-29 Power consumption specifications (O-210E-B)
Indoor ONT (I-020E-B and I-020E-H)
Table 10-30 provides the power consumption specifications for the I-020E-B and
I-020E-H indoor ONTs.
Table 10-30 Power consumption specifications (I-020E-B and I-020E-H)
Indoor ONT
All I-2xxM-x ONTs that use power supplies require 12 V DC input power supplies.
See the appropriate ONT data sheet for specific UPS support.
Indoor ONT (I-020G-F and I-020G-G)
Table 10-31 provides the power consumption specifications for the I-020G-F and
I-020G-G indoor ONTs.
Power consumption Specifications
Maximum power consumption Not exceeding 8 W with all services active
(2 Ethernet ports operational, 4 POTS off hook)
Minimum power consumption Not exceeding 5 W with all services idle
(2 Ethernet ports active, POTS on-hook)
Power consumption Specifications
Maximum power consumption Not exceeding 6.25 W with all services active
(1 Ethernet ports operational, 2 POTS off hook)
Minimum power consumption Not exceeding 4.75 W with all services idle
(1 Ethernet port active, POTS on-hook)
Power consumption Specifications
Maximum power consumption Not exceeding 4.7 W with all services active
(2 Ethernet ports operational)
Minimum power consumption Not exceeding 3.2 W with all services idle
(no Ethernet ports provisioned.)