42 —  FlexNet FMPS-150W UPS unit data sheet
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06 July 2008 42-7
3FE 51892 AAAA TCZZA Edition 01 ONT Product Information Manual
Battery recharge to 90% efficiency using two battery strings are defined as follows:
• load, 25 W: 13.6 h
• load, 100 W: 25.2 h
• load, 150 W: no recharge
The operating conditions are defined as follows:
• temperature range 1, with heater: −40°F to 115°F (−40°C to 46°C)
• temperature range 2, without heater: 14°F to 115°F (−10°C to 46°C)
• elevation: 0 to 10 000 ft above sea level (0 to 3000 m)
• humidity (non-condensing): 0% to 95% RH
The storage conditions are defined as follows:
• temperature range: −5°F to 185°F (−15°C to 85°C)
• humidity (non-condensing): 0% to 95% humidity
• elevation: 0 to 50 000 ft above sea level (0 to 15000 m)