EasyManua.ls Logo

Alcatel-Lucent 9500 MXC - Dual Protection Switching Criteria

Alcatel-Lucent 9500 MXC
916 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9500 MXC User Manual
3DB 23063 ADAA - Rev 004 July 2007 Vol. II-3-97
Service Restoration Times for Hot Standby and Diversity
Service restoration times (detection, switching and recovery) for a switch event
are:
Transmit Switch
• 200 ms maximum for a local alarm
• 20 seconds maximum for a remote-end command (silent transmitter event)
Receive Switch
• Switching is hitless for all alarm events except for a failure at the bus-drive
protection switch within the online designated RAC.
• 200 ms maximum for a bus-drive switch.
Dual Protection Switching Criteria
Currently dual protection is only offered with a frequency diversity master,
which means that only Rx (to the backplane bus) is switched; both subordinate
protected links are online transmitting (transmit protection criteria do not apply).
For restoration times refer to: Service Restoration Times for Dual Protection on
page 3-98.
Receive Switching Criteria, Frequency Diversity Master
RAC bus-drive switching is initiated between the two subordinate links under the
following conditions:
• RAC plug-in is missing or incorrect
• RAC component failure:
• RAC software load failure
• EEPROM failure
• Rx path failure:
• Rx synthesizer not locked
• RF IF synthesizer not locked
• Demodulator not locked
• ODU Tx cable IF synthesizer not locked
The 20 second period is set to prevent unwanted switching caused by
momentary path fade or other switching events.

Table of Contents

Related product manuals