9500 MXC User Manual
3DB 23063 ADAA - Rev 004 July 2007 Vol. IV-9-9
Figure 9-6. Example Circuits Screen for Figure 9-5 Requirements
Procedure for Configuring Circuits - Traffic
Before You Begin
• Before configuring circuits for an east-west ring, refer to Additional Rules for
an East-West PDH Ring on page 9-12, and to the Ring Network Planning and
Implementation Guide in Appendix A.
• Before configuring circuits to/from a DAC ES or DAC GE, refer to the
Additional Rules for DAC ES and DAC GE on page 9-13.
Item Description
1 In this example the maximum possible ring capacity is 32xE1 (32xE1 has been
configured on the east RAC and 63xE1 is available on the west DAC 155oM).
2 Shows the ring configured for 22xE1. Ring capacity is selected using the
up/down tabs.
3 As a result 10xE1 remains available for point-to-point traffic on the east RAC,
and 41xE1 on the east DAC 155oM. (Available capacity not used on the ring is
shown as point-to-point).
4 DATA 2 (DAC 16x) has been set for 4xE1 drop-insert ring circuits, leaving
18xE1 as pass-through ring circuits at this Node.
5 DAC 4 (DAC ES) has been set for 8x2.048 Mbps point-to-point east and west
(16 Mbps on Channel 1 and 16 Mbps on Channel 2).
1
2
3
4
5