EasyManua.ls Logo

Alcatel-Lucent 9500 MXC - Dac;Tributary Menu; DAC System;Controls Screen: PDH and SDH Dacs

Alcatel-Lucent 9500 MXC
916 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 15. Diagnostics
Vol. IV-15-56 Alcatel-Lucent
DAC/Tributary Menu
For a 9500 MXC Node and an IDU ES a DAC tributary screen opens to reflect
the DAC type selected.
For 9500 MXC PDH and SDH Terminals the tributary type (NxE1/DS1, STM1/
OC3) is fixed for the IDU type.
Refer to:
DAC System/Controls Screen: PDH and SDH DACs on page 15-56
Loopback and AIS Safety Timer Operation on page 15-58
PRBS Generation on page 15-58
Protected DAC Screens on page 15-60
DAC System/Controls Screen: PDH and SDH DACs
Figure 15-20 shows an NxE1/DS-1 DAC, which provides trib-by-trib selection
of:
Line facing loopback
Radio facing (bus facing) loopback
Transmit AIS
PRBS generator with G.821 data receiver
A loopback or AIS can be enabled on a trib (loopback and AIS selections are
mutually exclusive; only one can be selected per trib).
A loopback or AIS can be enabled on any number of tribs at the same time.
PRBS can only be enabled on one trib at a time.
Refer to Figure 15-25 on page 15-66 for DAC loopback points and loopback
directions.
The Event Browser and Alarm screens capture the application and subsequent
release of Link diagnostic options. While Link diagnostics are active:
The diagnostic icon is displayed in the CT status bar.
For a Node the NCC Test LED flashes orange.
For a Terminal the IDU Status LED flashes orange.