Chapter 7. Node and Terminal Plug-ins
Vol. IV-7-26 Alcatel-Lucent
DAC 16x, DAC 4x and IDU E1/DS1Trib Configuration on page 7-28
DAC 3xE3/DS3M Configuration on page 7-31
DAC 155o, 2x155o and 2x155e Configuration on page 7-36
DAC 155oM Configuration on page 7-38
DAC ES and IDU ES Configuration on page 7-46
DAC GE Configuration on page 7-57
Auxiliary Data and NMS Functions on page 7-84
AUX Configuration on page 7-88
Alarm I/O Configuration on page 7-90
Naming
DATA/DAC (Module) Name. A name can be entered or a name changed by
right-clicking within the DATA module in the System Summary screen, selecting
Rename, and typing. The default name is ‘unnamed’.
The name entered will appear in all CT screens where the DATA module
function is identified. Includes Plug-ins, Protection, Circuits, System
Summary, and System/Controls screens.
Trib Naming
. Trib names should relate to its circuit name to permit easy
association of trib with circuit when setting a DAC BER test using the circuit
loopback feature. Trib names are entered in the DAC Plug-ins screens; circuit
names are entered in the Circuits screen.
Tributary Protection
Tributary protection on a Node is provided by operating two identical DACs as a
protected pair. Refer to Node Protection on page 8-1 for configuration
information.
Tributary protection on a protected Terminal is provided by operating two
identical IDUs as a protected pair. Refer to Terminal Protection on page 8-17 for
configuration information.
Two tributary protection options are provided on the IDU 155o, three on the IDU
20x. Tributary protection and tributary always-on applies to both IDUs; hot
standby: no tributary protection applies only to the IDU 20x.
Tributary Protection (TT)
‘Y’ cables connect the paired DACs/IDUs to customer equipment.
In the Rx direction (from the customer) both DAC/IDUs receive data, but only
the online Rx DAC/IDU sends this data to the bus/radio.