EasyManua.ls Logo

Alcatel-Lucent 9500 MXC - DAC Protection Switching Criteria

Alcatel-Lucent 9500 MXC
916 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3. 9500 MXC Nodes
Vol. II-3-100 Alcatel-Lucent
setting of a time of day when an unwrap will occur providing all wrap conditions
have been cleared for a period not less than that set in the Error-free Timer. This
timer has a 1-hour window; if the conditions which caused the wrap are not
cleared by the Error-free Timer during this window, then Delay Ring Unwrap
resets for the same time the following day.
The System/Controls screen provides a countdown timer to indicate the time to
go before the ring will unwrap. Applies to both the Error-free Timer and Delay
Ring Unwrap Timer. (Counts down to zero).
DAC Protection Switching Criteria
The Tx and Rx tribs are independently switched. Switching is not hitless.
200 ms maximum restoration time for a Tx or Rx trib switch.
Trib protection is available for E3/DS3 and STM1/OC3 DACs, including DAC
3xE3/DS3M and DAC 155oM. Switch criteria are common for all DACs.
Refer to:
Tx Trib Switching
Rx Trib Switching
Tx Trib Switching
Transmitter switching to the alternate DAC transmitter is initiated for the
following local alarm conditions:
SW/HW failure:
Plug-in missing or incorrect
FPGA software load failure
LIU failure
Clock generator failure
Rx Trib Switching
Receiver switching to the alternate DAC receiver is initiated for the following
local alarm conditions:
SW/HW failure:
Plug-in missing or incorrect
FPGA software load failure
LIU failure
Clock generator failure
Tributary LOS