Vol. VI-B-40 Alcatel-Lucent
circuit has been configured but not classified as commissioned.
Recommended Actions
Go to the CT circuits screen and tick the commissioned/uncommissioned box to
show commissioned.
Additional Information
When a trib is commissioned, it and its associated circuit should be named. Trib
naming is done in the Plug-ins screen; circuit naming in the Circuits screen.
Trib n AIS
AIS received on tributary. This is a warning alarm.
Probable Cause
AIS has been detected on a trib input due to an alarm condition within the
connected equipment, or upstream from the directly connected equipment.
Recommended Actions
Investigate the AIS source, first in the directly connected equipment, and then in
its upstream connections.
AUX Alarms
Alarm Input (n)
AUX alarm input is active, where ‘n’ can be 1 to 6 for a Node, or 1 to 2 for a
Terminal. This is a warning alarm.
Probable Cause
AUX alarm input is active.
Recommended Actions
Investigate the cause of the activating event.
Additional Information
This alarm draws attention to a changed, active state on a configured AUX alarm