9500 MXC User Manual
3DB 23063 ADAA - Rev 004 July 2007 Vol. VI-B-35
Traffic Path Down
The radio path is down. True for non-protected and for protected/diversity
configurations. This is a critical alarm.
Probable Cause
Path loss or equipment malfunction.
Recommended Actions
1. Check for path loss.
Traffic will be affected in both directions.
A complete path loss will almost invariably be preceded by a low RSL and
BER alarms; check CT History and Event Browser screens and associated
event help.
2. Check equipment.
An equipment related path loss should be signalled by alarms from the
ODU, RAC, or NCC.
Such alarms may be at the local or remote end and may be one-way or
both-way traffic affecting.
Protection Cable Unplugged
Unable to detect the protection cable. This is a warning alarm.
Probable Cause
Cable not present/disconnected.
Recommended Actions
Check/install the protection cable.
DAC Alarms
LIU Failure
No communications with the LIU (line interface unit). This is a critical alarm.
Probable Cause
Equipment malfunction.