User's Manual 810 Document #: LTRT-10466
Mediant 500L MSBR
Parameter Description
[20] = local use 4 (local4)
[21] = local use 5 (local5)
[22] = local use 6 (local6)
[23]
= local use 7 (local7)
Web: CDR Session ID
CLI: cdr-seq-num
[CDRSyslogSeqNum]
Enables or disables the inclusion of the sequence number (S=) in
CDR Syslog messages.
[0] Disable
[1]
Enable (default)
Web: Activity Types to Report
via Activity Log Messages
CLI: config-system > logging >
activity-log
[ActivityListToLog]
Defines the operations (activities) in the Web interface that are
reported to a Syslog server.
[pvc] Parameters Value Change = Changes made on-the-fly to
parameters. Note that the ini file parameter,
EnableParametersMonitoring can also be used to set this
option, using values [0] (disable) or [1] (enable).
[afl] Auxiliary Files Loading = Loading of auxiliary files.
[dr] Device Reset = Resetting of the device through the
Maintenance Actions page.
Note: For this option to take effect, a device reset is required.
[fb] Flash Memory Burning = Saving configuration with burn to
flash (in the Maintenance Actions page).
[swu] Device Software Update = Software updates (i.e.,
loading of cmp file) through the Software Upgrade Wizard.
[ard] Access to Restricted Domains = Access to restricted Web
pages:
(1) ini parameters (AdminPage)
(2) General Security Settings
(3) Configuration File
(5) Software Upgrade Key Status
(7) Web & Telnet Access List
(8) Web User Accounts
[naa] Non-Authorized Access = Attempts to log in to the Web
interface with a false or empty username or password.
[spc] Sensitive Parameters Value Change = Changes made to
"sensitive" parameters:
(1) IP Address
(2) Subnet Mask
(3) Default Gateway IP Address
(4) ActivityListToLog
[ll] Login and Logout = Web login and logout attempts.
Note: For the ini file parameter, enclose values in single quotation
marks, for example: ActivityListToLog = 'pvc', 'afl', 'dr', 'fb', 'swu',
'ard', 'naa', 'spc'.
[EnableParametersMonitoring]
Enables the monitoring, through Syslog messages, of parameters
that are modified on-the-fly.
[0] = (Default) Disable
[1] = Enable
CLI: oamp-default-network-src
data/voip
[OAMPDefaultNetworkSource]
Defines the network interface from where the device sends Syslog
messages to a Syslog server.
[0] Data (default) = Syslog messages are sent from the WAN
interface.
[1] VoIP= Syslog messages are sent from the VoIP LAN