Version 6.4 233 March 2012
SIP User's Manual 18. GW and IP to IP
Parameter Description
DTMF Max Detection Time
[CasStateMachineDTMFMaxOnDetecti
onTime]
Detects digit maximum on time (according to DSP
detection information event) in msec units.
The value must be a positive value. The default value is -
1 (use value from CAS state machine).
DTMF Min Detection Time
[CasStateMachineDTMFMinOnDetectio
nTime]
Detects digit minimum on time (according to DSP
detection information event) in msec units. The digit time
length must be longer than this value to receive a
detection. Any number may be used, but the value must
be less than
CasStateMachineDTMFMaxOnDetectionTime.
The value must be a positive value. The default value is -
1 (use value from CAS state machine).
MAX Incoming Address Digits
[CasStateMachineMaxNumOfIncoming
AddressDigits]
Defines the limitation for the maximum address digits that
need to be collected. After reaching this number of digits,
the collection of address digits is stopped.
The value must be an integer. The default value is -1 (use
value from CAS state machine).
MAX Incoming ANI Digits
[CasStateMachineMaxNumOfIncoming
ANIDigits]
Defines the limitation for the maximum ANI digits that
need to be collected. After reaching this number of digits,
the collection of ANI digits is stopped.
The value must be an integer. The default value is -1 (use
value from CAS state machine).
Collet ANI
[CasStateMachineCollectANI]
In some cases, when the state machine handles the ANI
collection (not related to MFCR2), you can control the
state machine to collect ANI or discard ANI.
[0] No = Don't collect ANI.
[1] Yes = Collect ANI.
[-1] Default = Default value -
machine.
Digit Signaling System
[CasStateMachineDigitSignalingSyste
m]
Defines which Signaling System to use in both directions
(detection\generation).
[0] DTMF = Uses DTMF signaling.
[1] MF = Uses MF signaling (default).
[-1] Default = Default value -
machine.