SIP User's Manual 620 Document #: LTRT-83310
Mediant 600 & Mediant 1000
Parameter Description
[0] Use Current Condition = The condition entered in this row
must be matched in order to perform the defined action
(default).
[1] Use Previous Condition = The condition of the rule
configured directly above this row must be used in order to
perform the defined action. This option allows you to configure
multiple actions for the same condition.
For example, the below configuration changes the user part of the
SIP From header to 200:
MessageManipulations 1 = 0, Invite.Request, , Header
.From.Url.User,
2, 200, 0;
Notes:
This table can include up to 200 indices (where 1 is the first index).
For a description of the syntax that can be used for this table, see
'SIP Message Manipulation Syntax' on page 789.
You must enclose a string in a single apostrophe. If you are using
multiple strings, then the entire string must also be enclosed in
double apostrophe, for example, "<sip:' + header.from.url.user +
'@domain.com>'".
For a description on configuring ini file table parameters, see
'Configuring ini File Table Parameters' on page 84.
A.10 Coders and Profile Parameters
The profile parameters are described in the table below.
Table A-32: Profile Parameters
Parameter Description
Coders Table / Coder Groups Table
Web: Coders
Table/Coder Group
Settings
EMS: Coders Group
[CodersGroup0]
[CodersGroup1]
[CodersGroup2]
[CodersGroup3]
[CodersGroup4]
This parameter table defines the device's coders. Up to five groups of coders
can be defined, where each group can consist of up to 10 coders. The first
Coder Group is the default coder list and the default Coder Group. These
Coder Groups can later be assigned to IP or Tel Profiles.
The format of this parameter is as follows:
[ CodersGroup0]
FORMAT CodersGroup0_Index = CodersGroup0_Name,
CodersGroup0_pTime, CodersGroup0_rate, CodersGroup0_PayloadType,
CodersGroup0_Sce;
[ \CodersGroup0 ]
Where,
Index = Coder entry 0-9, i.e., up to 10 coders per group.
Name = Coder name.
Ptime = Packetization time (ptime) - how many coder payloads are
combined into a single RTP packet.
Rate = Packetization rate.
PayloadType = Identifies the format of the RTP payload.
Sce = Enables silence suppression:
[0] Disabled (default)
[1] Enabled
For example, below are defined two Coder Groups (0 and 1):