EasyManua.ls Logo

AudioCodes Mediant 600 - SIP Call Routing Examples; SIP Call Flow Example

AudioCodes Mediant 600
844 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIP User's Manual 350 Document #: LTRT-83310
Mediant 600 & Mediant 1000
18.8 SIP Call Routing Examples
18.8.1 SIP Call Flow Example
The SIP call flow (shown in the following figure), describes SIP messages exchanged
between two devices during a basic call. In this call flow example, device (10.8.201.158)
with phone number ‘6000’ dials device (10.8.201.161) with phone number ‘2000’.
Figure 18-36: SIP Call Flow
F1 INVITE (10.8.201.108 >> 10.8.201.161):
INVITE sip:2000@10.8.201.161;user=phone SIP/2.0
Via: SIP/2.0/UDP 10.8.201.108;branch=z9hG4bKacsiJkDGd
From: <sip:6000@10.8.201.108>;tag=1c5354
To: <sip:2000@10.8.201.161>
Call-ID: 534366556655skKw-6000--2000@10.8.201.108
CSeq: 18153 INVITE
Contact: <sip:8000@10.8.201.108;user=phone>
User-Agent: Audiocodes-Sip-Gateway/Mediant 1000/v.6.40.010.006
Supported: 100rel,em
Allow: REGISTER,OPTIONS,INVITE,ACK,CANCEL,BYE,
NOTIFY,PRACK,REFER,INFO
Content-Type: application/sdp
Content-Length: 208
v=0
o=AudiocodesGW 18132 74003 IN IP4 10.8.201.108
s=Phone-Call
c=IN IP4 10.8.201.108
t=0 0
m=audio 4000 RTP/AVP 8 96
a=rtpmap:8 pcma/8000

Table of Contents

Other manuals for AudioCodes Mediant 600

Related product manuals