EasyManua.ls Logo

AudioCodes Mediant 600 - Message Waiting Indication Parameters

AudioCodes Mediant 600
844 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 6.4 665 March 2012
SIP User's Manual A. Configuration Parameters Reference
Parameter Description
[1] Enable
Web: AS Subscribe
IPGroupID
[ASSubscribeIPGroupID]
Defines the IP Group ID that contains the Application server for
Subscription.
The valid value range is 1 to 8. The default is -1 (i.e., not configured).
Web: NRT Retry
Subscription Time
[NRTSubscribeRetryTime]
Defines the Retry period (in seconds) for Dialog subscription if a
previous request failed.
The valid value range is 10 to 7200. The default is 120.
Web: Call Forward Ring
Tone ID
[CallForwardRingToneID]
Defines the ringing tone type played when call forward notification is
accepted.
The valid value range is 1 to 5. The default is 1.
A.12.5.4 Message Waiting Indication Parameters
The message waiting indication (MWI) parameters are described in the table below.
Table A-44: MWI Parameters
Parameter Description
Web: Enable MWI
EMS: MWI Enable
[EnableMWI]
Enables Message Waiting Indication (MWI).
[0] Disable = Disabled (default).
[1] Enable = MWI service is enabled.
Notes:
This parameter is applicable only to FXS interfaces.
The device supports only the receipt of SIP MWI NOTIFY
messages (the device doesn't generate these messages).
For more information on MWI, see 'Message Waiting Indication' on
page 301.
Web/EMS: MWI Analog
Lamp
[MWIAnalogLamp]
Enables the visual display of MWI.
[0] Disable = Disable (default).
[1] Enable = Enables visual MWI by supplying line voltage of
approximately 100 VDC to activate the phone's lamp.
Notes:
This parameter is applicable only for FXS interfaces.
This parameter can also be configured per Tel Profile (using the
TelProfile parameter).
Web/EMS: MWI Display
[MWIDisplay]
Enables sending MWI information to the phone display.
[0] Disable = MWI information isn't sent to display (default).
[1] Enable = The device generates an MWI message (determined
by the parameter CallerIDType), which is displayed on the MWI
display.
Note:
This parameter is applicable only to FXS interfaces.
This parameter can also be configured per Tel Profile (using the
TelProfile parameter).
Web: Subscribe to MWI
EMS: Enable MWI
Subscription
Enables subscription to an MWI server.
[0] No = Disables MWI subscription (default).
[1] Yes = Enables subscription to an MWI server (defined by the

Table of Contents