SIP User's Manual 24 Document #: LTRT-83310
Mediant 600 & Mediant 1000
Figure 2-2: Connecting to Serial Port for Initial Connectivity – Mediant 600
2. Establish a serial communication link with the device using a terminal emulator
program (such as HyperTerminal) with the following communication port settings:
• Baud Rate: 115,200 bps
• Data Bits: 8
• Parity: None
• Stop Bits: 1
• Flow Control: None
3. At the prompt, type the following command to access the configuration folder, and
then press Enter:
conf
4. At the prompt, type the following command to view the current network settings, and
then press Enter:
GCP IP
5. At the prompt, typing the following command to change the network settings, and then
press Enter:
SCP IP <ip_address> <subnet_mask> <default_gateway>
You must enter all three network parameters, each separated by a space, for
example:
SCP IP 10.13.77.7 255.255.0.0 10.13.0.1
6. At the prompt, type the following command to save the settings and reset the device,
and then press Enter:
SAR