Version 6.4  555  March 2012 
SIP User's Manual   A. Configuration Parameters Reference 
Parameter  Description 
Web: Deny Authentication Timer 
[DenyAuthenticationTimer] 
Defines the time (in seconds) that login to the Web interface is 
denied for a user that has reached maximum login attempts as 
defined by the DenyAccessOnFailCount parameter. Only after 
this time expires can the user attempt to login from the same IP 
address. 
The default is 0. 
Web: Display Login Information 
[DisplayLoginInformation] 
Enables display of user's login information on each successful 
login attempt. 
  [0] = Disable (default) 
  [1] = Enable 
[EnableMgmtTwoFactorAuthenti
cation] 
Enables Web login authentication using a third-party, smart 
card. 
  [0] = Disable (default) 
  [1] = Enable 
When enabled, the device retrieves the Web user’s login 
username from the smart card, which is automatically displayed 
(read-only) in the Web Login screen; the user is then required to 
provide only the login password. 
Typically, a TLS connection is established between the smart 
card and the device’s Web interface, and a RADIUS server is 
implemented to authenticate the password with the username. 
Thus, this feature implements a two-factor authentication - what 
the user has (the physical card) and what the user knows (i.e., 
the login password). 
[DisableWebTask] 
Enables device management through the Web interface. 
  [0] = Enable Web management (default). 
  [1] = Disable Web management. 
Note: For this parameter to take effect, a device reset is 
required. 
 
[HTTPport] 
Defines the LAN HTTP port for Web management (default is 
80). To enable Web management from the LAN, configure the 
desired port. 
Note: For this parameter to take effect, a device reset is 
required. 
EMS: Disable WEB Config 
[DisableWebConfig] 
Determines whether the entire Web interface is read-only. 
  [0] = Enables modifications of parameters (default). 
  [1] = Web interface is read-only. 
When in read-only mode, parameters can't be modified. In 
addition, the following pages can't be accessed: 'Web User 
Accounts', 'Certificates', 'Regional Settings', 'Maintenance 
Actions' and all file-loading pages ('Load Auxiliary Files', 
'Software Upgrade Wizard', and 'Configuration File'). 
Notes: 
  For this parameter to take effect, a device reset is required. 
  To return to read/write after you have applied read-only 
using this parameter (set to 1), you need to reboot your 
device with an ini file that doesn't include this parameter, 
using the BootP/TFTP Server utility (refer to the Product 
Reference Manual).