Loading...
Version 6.4 565 March 2012
SIP User's Manual A. Configuration Parameters Reference
Parameter Description
[18] = local use 2 (local2)
[19] = local use 3 (local3)
[20] = local use 4 (local4)
[21] = local use 5 (local5)
[22] = local use 6 (local6)
[23] = local use 7 (local7)
Web: Activity Types to
Report via Activity Log
Messages
[ActivityListToLog]
Defines the Activity Log mechanism of the device, which sends log
messages (to a Syslog server) for reporting certain types of Web
operations according to the below user-defined filters.
[pvc] Parameters Value Change = Changes made on-the-fly to
parameters.
[afl] Auxiliary Files Loading = Loading of auxiliary files.
[dr] Device Reset = Reset of device via the 'Maintenance Actions
page.
Note: For this option to take effect, a device reset is required.
[fb] Flash Memory Burning = Burning of files or parameters to flash
(in 'Maintenance Actions page).
[swu] Device Software Update = cmp file loading via the Software
Upgrade Wizard.
[ard]
Access to Restricted Domains = Access to restricted domains,
which include the following Web pages:
(1) ini parameters (AdminPage)
(2) General Security Settings
(3) Configuration File
(4) IP Security Proposal / IP Security Associations Tables
(5) Software Upgrade Key Status
(6) Firewall Settings
(7) Web & Telnet Access List
(8) WEB User Accounts
[naa] Non-Authorized Access = Attempt to access the Web
interface with a false or empty user name or password.
[spc] Sensitive Parameters Value Change = Changes made to
sensitive parameters:
(1) IP Address
(2) Subnet Mask
(3) Default Gateway IP Address
(4) ActivityListToLog
[ll] Login and Logout = Every login and logout attempt.
For example: ActivityListToLog = 'pvc', 'afl', 'dr', 'fb', 'swu', 'ard', 'naa',
'spc'
Note: For the ini file, values must be enclosed in single quotation
marks.
[FacilityTrace]
Enables ISDN traces of Facility Information Elements (IE) for ISDN call
diagnostics. This allows you to trace all the parameters contained in
the Facility IE and view them in the Syslog.
[0] Disable (default)
[1] Enable
Note: For this feature to be functional, the GWDebugLevel parameter
must be enabled (i.e., set to at least level 1).