SIP User's Manual 632 Document #: LTRT-83310
Mediant 600 & Mediant 1000
Parameter Description
[DspTemplates]
FORMAT DspTemplates_Index = DspTemplates_DspTemplateNumber,
DspTemplates_DspResourcesPercentage;
[\DspTemplates]
For example, to load DSP Template 1 to 50% of the DSPs, and DSP
Template 2 to the remaining 50%, the table is configured as follows:
DspTemplates 0 = 1, 50;
DspTemplates 1 = 2, 50;
Notes:
The DSPVersionTemplateNumber parameter is ignored when the
DSPTemplates parameter is configured.
For a list of supported DSP templates, see DSP Templates on page
835.
Web: DSP Version
Template Number
EMS: Version Template
Number
[DSPVersionTemplateNu
mber]
Determines the DSP template used by the device. Each DSP template
supports specific coders, channel capacity, and features.
The default is DSP template 0.
You can load different DSP templates to analog and digital modules
using the syntax DSPVersionTemplateNumber=xy
where:
x = 0 or 1 for DSP templates of analog modules
y = 0 to 5 for DSP templates of digital and MPM modules
Notes:
For this parameter to take effect, a device reset is required.
For a list of supported DSP templates, see DSP Templates on page
835.