SIP User's Manual 716 Document #: LTRT-83310
Mediant 600 & Mediant 1000
Parameter Description
BrokenConnectionEventTimeout parameter.
This feature is applicable only if the RTP session is used
without Silence Compression. If Silence Compression is
enabled, the device doesn't detect a broken RTP connection.
During a call, if the source IP address (from where the RTP
packets are received) is changed without notifying the device,
the devic
e filters these RTP packets. To overcome this, set the
DisconnectOnBrokenConnection parameter to 0; the device
doesn't detect RTP packets arriving from the original source IP
address and switches (after 300 msec) to the RTP packets
arriving from the new source IP address.
This parameter can also be configured per IP Profile, using the
IPProfile parameter (see 'Configuring IP Profiles' on page
219).
Web: Broken Connection
Timeout
EMS: Broken Connection Event
Timeout
[BrokenConnectionEventTimeo
ut]
Defines the time period (in 100-msec units) after which a call is
disconnected if an RTP packet is not received.
The valid range is from 3 (i.e., 300 msec) to an unlimited value
(e.g., 20 hours). The default value is 100 (i.e., 10000 msec or 10
seconds).
Notes:
This parameter is applicable only if the parameter
DisconnectOnBrokenConnection is set to 1.
Currently, this feature functions only if Silence Suppression is
disabled.
Web: Disconnect Call on Silence
Detection
EMS: Disconnect On Detection
Of Silence
[EnableSilenceDisconnect]
Determines whether calls are disconnected after detection of
silence.
[1] Yes = The device disconnects calls in which silence occurs
(in both call directions) for more than a user-defined time.
[0] No = Call is not disconnected when silence is detected
(default).
The silence duration can be configured by the
FarEndDisconnectSilencePeriod parameter (default 120).
Note: To activate this feature, set the parameters
EnableSilenceCompression and
FarEndDisconnectSilenceMethod to 1.
Web: Silence Detection Period
[sec]
EMS: Silence Detection Time Out
[FarEndDisconnectSilencePeri
od]
Defines the duration of the silence period (in seconds) after which
the call is disconnected.
The range is 10 to 28,800 (i.e., 8 hours). The default is 120
seconds.
Note: For this parameter to take effect, a device reset is required.
Web: Silence Detection Method
[FarEndDisconnectSilenceMeth
od]
Determines the silence detection method.
[0] None = Silence detection option is disabled.
[1] Packets Count = According to packet count.
[2] Voice/Energy Detectors = N/A.
[3] All = N/A.
Note: For this parameter to take effect, a device reset is required.
[FarEndDisconnectSilenceThre
shold]
Defines the threshold of the packet count (in percentages) below
which is considered silence by the device.
The valid range is 1 to 100%. The default is 8%.
Notes:
This parameter is applicable only if silence is detected

Table of Contents