SIP User's Manual 782 Document #: LTRT-83310
Mediant 600 & Mediant 1000
Parameter Description
Web: CAS File
EMS: Trunk Cas Table Index
[CASFileName_x]
Defines the CAS file name (e.g., 'E_M_WinkTable.dat'), which
defines the CAS protocol (where x denotes the CAS file ID 0 to 7).
It is possible to define up to eight different CAS files by repeating
this parameter. Each CAS file can be associated with one or more
of the device's trunks, using the parameter CASTableIndex or it can
be associated per B-channel using the parameter
CASChannelIndex.
Note: For this parameter to take effect, a device reset is required.
Web: Dial Plan
EMS: Dial Plan Name
[CasTrunkDialPlanName_x]
Defines the Dial Plan name (up to 11-character strings) that is used
on a specific trunk (denoted by x).
Web: Dial Plan File
EMS: Dial Plan File Name
[DialPlanFileName]
Defines the name (and path) of the Dial Plan file (defining dial
plans). This file should be constructed using the DConvert utility
(refer to the Product Reference Manual).
[UserInfoFileName]
Defines the name (and path) of the file containing the User
Information data.