3 608 878 300 Tightening Technology | Bosch Rexroth AG 133/641
System 350 | 3 608 878 300/2019-03
ES LED Green ErgoSpin LED Green: Sets the green ErgoSpin LED
This signal is available as of version V2.300 of the Rexroth Tightening System 350.
Input signal used for:
• Tightening channel (EsLEDGreen)
• Communication unit in single-channel operation (CH x.y EsLEDGreen)
Using this signal, a superior control can activate the green LED on the hand-held nutrunner from outside.
This signal can only be activated if it has been assigned in the PLC assignment table. Once one of the
EsLEDGreen, EsLEDRed and EsLEDYellow signals has been assigned in the PLC assignment table, the
external controller will assume the task of activating the LED. i.e. the present display of OK or NOK and
enabling by the tightening system will no longer be applicable.
ES LED Red ErgoSpin LED Red: Sets the red ErgoSpin LED
This signal is available as of version V2.300 of the Rexroth Tightening System 350.
Input signal used for:
• Tightening channel (EsLEDRed)
• Communication unit in single-channel operation (CH x.y EsLEDRed)
Using this signal, a superior control can activate the red LED on the hand-held nutrunner from outside.
This signal can only be activated if it has been assigned in the PLC assignment table. Once one of the
EsLEDGreen, EsLEDRed and EsLEDYellow signals has been assigned in the PLC assignment table, the
external controller will assume the task of activating the LED. i.e. the present display of OK or NOK and
enabling by the tightening system will no longer be applicable.
ES LED Yellow ErgoSpin LED Yellow: Sets the yellow ErgoSpin LED
This signal is available as of version V2.300 of the Rexroth Tightening System 350.
Input signal used for:
• Tightening channel (EsLEDYellow)
• Communication unit in single-channel operation (CH x.y EsLEDYellow)
Using this signal, a superior control can activate the yellow LED on the hand-held nutrunner from outside.
This signal can only be activated if it has been assigned in the PLC assignment table. Once one of the
EsLEDGreen, EsLEDRed and EsLEDYellow signals has been assigned in the PLC assignment table, the
external controller will assume the task of activating the LED. i.e. the present display of OK or NOK and
enabling by the tightening system will no longer be applicable.
GO_SetRef Set Geared Offset Reference Point: Flat output drive offset position reference point
This signal is available as of version V2.500 of the Rexroth Tightening System 350.
Input signal used for:
• Tightening channel (GO_SetRef)
• Communication unit in single-channel operation (
CH x.y GO_SetRef)
This signal is only active for tightening channels with ErgoSpin. The signal is only updated outside of the
tightening operation.
This signal is only active for tightening channels with ErgoSpin. The signal is only updated outside of the
tightening operation.
This signal is only active for tightening channels with ErgoSpin. The signal is only updated outside of the
tightening operation.