3 608 878 300 Tightening Technology | Bosch Rexroth AG 159/641
System 350 | 3 608 878 300/2019-03
CwAND E Clock wise AND AND operation for tightening program.
CyCmp A Cycle Complete End of tightening.
DisRp E Disable Report Results output to subsequent tightening
application suppressed
En E Enable Reaction to a nutrunner start is not triggered
before En "high".
ES LED Green E ErgoSpin LED Green Sets the green ErgoSpin LED.
ES LED Gr Ack A ErgoSpin LED Green acknowledge Acknowledges that the green ErgoSpin LED
has been set.
ES LED Red E ErgoSpin LED Red Sets the red ErgoSpin LED.
ES LED Re Ack A ErgoSpin LED Red acknowledge Acknowledges that the red ErgoSpin LED has
been set.
ES LED Yellow E ErgoSpin LED Yellow Sets the yellow ErgoSpin LED.
ES LED Ye Ack A ErgoSpin LED Yellow acknowledge Acknowledges that the yellow ErgoSpin LED
has been set.
FtpF A Ftp Fault Error during transfer to the FTP server.
GradAvrH A Gradient average too high The gradient average value exceeds the defined
tolerance window.
GradAvrL A Gradient average too low The gradient average value is below the defined
tolerance window.
GradH A Gradient too high The gradient is above the defined tolerance
window.
GradL A Gradient too low The gradient is below the defined tolerance
window.
InCy A In Cycle This signal signals the start of a tightening
application to the partner controller.
InCyCmp A In Cycle Complete Time period elapsing while tightening is active,
including evaluation and completed results
output.
InCyCcw A In Cycle Counter clock wise This signal reports that the tightening
application is active.
InCyEv A In Cycle Evaluation Time period elapsing while tightening is active,
including completed evaluation.
Job Abort E Job abort Aborts a job
Job Ack 0-7 A Job acklowledge Acknowledges the selected job
Job CyCmp A Job finished The job is finished
Job Enable E Job enable Activates a job
Job InCy A Job running The job is active
Job Nok A Job Not Ok The job result is not okay
Job Ok A Job Ok The job result is okay
Job Rdy A Job ready The job is ready
Job ResRs E Job reset result Resets a result
Job Start E Job run Starts a job
Job 0-7 E Job number Selects a job
JobIn 0-31 E Job in bit Job-specific input signal
JobOutRs E Job out reset Reset job output signals JobOut 0 - 31
JobOut0-31 A Job out bit Job-specific output signal
MStop A Motor-breaker Motor stop at least at one tightening channel of
the modular system. Signal change from "high"
to "low" only with use of LTE350D, LTS350D or
CS351X-DNK (signal change with LTE350D or
LTS350D as of V2.600 of the Rexroth
Tightening System).
NF A No Fault If this signal is "low", all the tightening
processes/applications are canceled.
Nok A Not OK This signal indicates that the tightening
application or tightening process was evaluated
with NOK.
Signals
1
CH x.y
E/A Function channel x.y ... Description