160/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
NokAc E Not OK Acknowledge Restart after NOK tightening is prevented.
Ok A OK This signal indicates that the tightening
application or KE tightening process was
evaluated with OK.
Prog0-7 E Program 0-7 Binary coded program number to tightening
controller.
RC0-4 A Rework Code Bit 0-4 Binary coded rework code.
Rdy A Ready Tightening application can only be started once
this signal is set to "high".
RedH A Redundancy too high The redundancy is above the defined tolerance
window.
ResRs E Reset Result PLC signals of monitoring functions and
CyCmp OK and SO x NOK are set.
CyCmp OK and monitoring signals like TorqH
are reset and NOK is set.
SEn E Signal Enable Enable channel x.y signals.
SEnAc A Signal Enable Acknowledge Acknowledge enable the signals
of channel x.y
StartBn A Start switch Status of the start switch on the ErgoSpin.
StickSlipH A Stick Slip Too High The number of stick slips is above the defined
tolerance window.
TimeH A Time too high The time is above the defined tolerance window.
ToolBn A Tool button Status of the tool button on the ErgoSpin.
TorqAvrH A Torque average too high The average torque value is above the defined
tolerance window.
TorqAvrL A Torque average too low The torque average value is below the defined
tolerance window.
TorqCtrH A Torque control too high The maximum torque control is above the
defined limit.
TorqCtrL A Torque control too low The tightening torque is below the defined limit.
TorqH A Torque too high The torque is above the defined tolerance
window.
TorqL A Torque too low The torque is below the defined tolerance
window.
TorqMaxH A Torque max too high The maximum torque is above the defined
tolerance window.
TorqMinL A Torque min too low The minimum torque is below the defined
tolerance window.
TorqRelH A Torque relative too high The relative torque is below the defined
tolerance window.
TorqRelL A Torque relative too low The relative torque is below the defined
tolerance window.
TorqRgeH A Torque range too high The torque range is above the defined tolerance
window.
TorqRgeL A Torque range too low The torque range is below the defined tolerance
window.
TrigOut A Trigger Out Trigger output is set as soon as the set
condition has been reached.
UsrIn1 E User Input 1 External input signal with program functions.
UsrIn2 E User Input 2 External input signal with program functions.
YieldH A Yield too high The yield point was reached.
1 CH x.y (fastening channel) tightening channel
2 As of version V2.600 of the Rexroth Tightening System 350, this signal is replaced by the MntTool signal.
Signals
1
CH x.y
E/A Function channel x.y ... Description
The KE control interface can be used to access single-channel signals. The extension Ch x.y is preset in
addition to the single-channel signal, e.g. Ch 1.2 CyCmp.