238/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
Tightening application results block
The entire result of an application is output after all the participating tightening channels have finished the
tightening and contains the entire result of the application and the results (OK/NOK/NOK_Bypass) of the
participating channels. The output format is as shown in Table 6–19.
Results file of a tightening application with two channels, each with three documented
steps
The following two pages contain the results printouts of the same tightening application. Case 1 OK
result, case 2 NOK result.
Table 6–19: Example for a results block of a tightening application
Character position Description
0+ 10+ 20+ 30+ 40+ 50+ 60+
0 1 2 3 4 56 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
_
Start trigger
**KE3
5 0 * *
Hardware identifier
D_ J J J
J - MM- TT_H_HH: MM: S S
Date, time
L_YYY
Y Y YY ____FO_ Y Y _ _______ OK
KE cycle counter, application no.,
result
1
QC_ Y Y Y Y Y _ ____Name _ b bbbbbbb b b b bbbbbbb b b
Quality code, application name (20
characters)
IDCod
e _ b b bbbbbbb b b b bbbbbbb b
ID code ("IDCode" plus max 64
characters)
OK _ _ _
_ _ _ _ ____CH_ o o . k______ P _ YY______ _ _ _ SST_ bbb b b b b
Res., channel no., prog. no.,
tightening position name
2
NOK_ _ _ _ _ _ ____CH_ o o . k______ P_ Y Y______ _ _ _ SST_ bbb b b b b
Res., channel no., prog. no.,
tightening position name
2
NOK_ By p a s s___CH_ o o . k______ P _ Y Y______ _ _ _ SST_ bbb b b b b
Res., channel no., prog. no.,
tightening position name
2
End trigger
1 An OK tightening is shown here.
2 One line per tightening position. Possible results for each channel are OK, NOK, and NOK_Bypass.