6.3.4.9 Transmission times
Transmission times depend on the configuration of the RS232 interface. Data rates of 300 to 19200
baud are possible. Table 6–43 shows the expected transmission times for typical applications:
Table 6–43: Data sets for transmission and the necessary transmission times
Application Transmission time (seconds)
at 19200 baud
Channels Format Actual/set values
Single channel Binary Actual and set values 0,2
Single channel Binary Actual values 0,1
Single channel ASCII Actual and set values 0,3
Single channel ASCII Actual values 0,2
Application, 1 channel Binary Actual and set values 0,2
Application, 1 channel Binary Actual values 0,2
Application, 1 channel ASCII Actual and set values 0,4
Application, 1 channel ASCII Actual values 0,3
Application, 4 channels Binary Actual and set values 0,4
Application, 4 channels Binary Actual values 0,3
Application, 4 channels ASCII Actual and set values 0,9
Application, 4 channels ASCII Actual values 0,6
Application, 24 channels Binary Actual and set values 1,7
Application, 24 channels Binary Actual values 1,1
Application, 24 channels ASCII Actual and set values 4.2
Application, 24 channels ASCII Actual values 2.4