344/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
MID 0002 revision 002
MID 0002 revision 003
Channel ID The first two characters of a channel name are used as channel ID. A
channel name consists of the channel ID and the name of the controller,
both of which are separated by a space.
The value consists of two ASCII characters.
ID 02
2
Value range 01 – 20
Presetting 01, means no channel or wrong channel
Example:
Channel ID 04 tightening channel
Value 04
2
Controller name The second part of the channel name is used as the controller name.
The value consists of 25 ASCII characters.
ID 03
2
Value range 0x20 – 0x7F
Presetting ***, means no controller name
Example:
Controller name 04 tightening channel
Value Tightening channel
25
Data length revision 001
37
Table 6–77: MID 002 revision 002
Parameter Comments Bytes
This revision includes the information from revision 001 and the following additional information:
Manufacturer code The value consists of three ASCII characters.
ID 04
2
Fixed value BRC
3
Data length revision 002 (= data length revision 001 + data length revision 002)
42
Table 6–78: MID 002 revision 003
Parameter Comments Bytes
This revision includes the information from revision 002 and the following additional information:
Open Protocol version The Open Protocol version is transferred.
The value consists of 19 ASCII characters.
ID 05
2
Value range 0x20 – 0x7F
Presetting -
Example:
Open Protocol version 7.0 version 34
Value 7.0 version 34
19
Software version The firmware version for the CS351 or KE350 is transferred.
The value consists of 19 ASCII characters.
ID 06
2
Value range 0x20 – 0x7F
Presetting -
Example:
Software version KE V2.100 release
Value KE V2.100 release
19
Table 6–76: MID 0002 revision 001
Parameter Comments Bytes