EasyManua.ls Logo

Bosch Rexroth Tightening System 350 - Page 345

Bosch Rexroth Tightening System 350
641 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 608 878 300 Tightening Technology | Bosch Rexroth AG 345/641
System 350 | 3 608 878 300/2019-03
Example:
Using the values from the example above, the value of the data field for revision 2 would be as follows:
010003020403tightening channel 04BRC
Meanings of the individual values:
01: Cell ID
0003: Cell ID value
02: Channel ID
04: Channel ID value
03: ID Controller name
Tightening channel : Controller name value
04: Manufacturer code ID
BRC: Manufacturer code fixed value
MID 0003 Communication stop
6.7.7.4 Request responses
MID 0004 Command error
Tool software version CS351 compact system: Firmware version for the hand-held nutrunner
KE350: Either the firmware version for the hand-held nutrunner or the
primary transducer for the tightening spindle in the first hand-held
nutrunner
The value consists of 19 ASCII characters.
ID 07
2
Value range 0x20 – 0x7F
Presetting -
Example:
Tool software version 1.00A0
Value 1.00A0
19
Data length revision 003 (= data length revision 002 + data length revision 003)
105
Table 6–78: MID 002 revision 003
Parameter Comments Bytes
Sent by: superordinate computer
Ends the command connection.
Note: After this command has been received, the tightening controller will only respond to the communication start
command (MID 0001).
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
Command accepted 0005
Sent by: Tightening controller
The tightening controller uses this message if a request cannot be fulfilled for some reason.
Note: -
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: Data 6 bytes
Possible response: none

Table of Contents