3 608 878 300 Tightening Technology | Bosch Rexroth AG 345/641
System 350 | 3 608 878 300/2019-03
Example:
Using the values from the example above, the value of the data field for revision 2 would be as follows:
010003020403tightening channel 04BRC
Meanings of the individual values:
• 01: Cell ID
• 0003: Cell ID value
• 02: Channel ID
• 04: Channel ID value
• 03: ID Controller name
• Tightening channel : Controller name value
• 04: Manufacturer code ID
• BRC: Manufacturer code fixed value
MID 0003 Communication stop
6.7.7.4 Request responses
MID 0004 Command error
Tool software version – CS351 compact system: Firmware version for the hand-held nutrunner
– KE350: Either the firmware version for the hand-held nutrunner or the
primary transducer for the tightening spindle in the first hand-held
nutrunner
The value consists of 19 ASCII characters.
ID 07
2
Value range 0x20 – 0x7F
Presetting -
Example:
Tool software version 1.00A0
Value 1.00A0
19
Data length revision 003 (= data length revision 002 + data length revision 003)
105
Table 6–78: MID 002 revision 003
Parameter Comments Bytes
Sent by: superordinate computer
Ends the command connection.
Note: After this command has been received, the tightening controller will only respond to the communication start
command (MID 0001).
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
Command accepted 0005 –
Sent by: Tightening controller
The tightening controller uses this message if a request cannot be fulfilled for some reason.
Note: -
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: Data 6 bytes
Possible response: none