346/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
Example:
The select tightening program request (MID 0018) has failed, as the tightening program number did not
exist in the tightening controller.
MID 0005 Command accepted
Table 6–79: MID 0004 revision 001
Parameter Comments Bytes
MID MID of the failed request
ID -
Value range 0000 – 9999
Presetting -
Example:
MID 18
Value 0018
4
Error number For possible error numbers, see Table 6–125.
ID -
Value range 00 – 99
Presetting -
Example:
Error number 2
Value 02
2
Data length revision 001
6
MID 0018
Error no. 02
Data field value 001802
Sent by: Tightening controller
With this message, the tightening controller confirms that the last request sent by the superior computer has been
accepted.
Note: -
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: Data 4 bytes
Possible response: none
Table 6–80: MID 0005 revision 1
Parameter Comments Bytes
MID MID of the accepted request
ID -
Value range 0000 – 9999
Presetting -
Example:
MID 18
Value 0018
4
Data length revision 001
4