348/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
6.7.7.5 Tightening program messages
MID 0010 Request to upload tightening program/tightening application numbers
MID 0011 Response to upload of tightening program/tightening application numbers
Sent by:
superordinate computer
Request of all existing tightening program or tightening application numbers
Note: -
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
Response to upload of tightening
program/tightening application numbers
0011 All valid tightening program or tightening application
numbers in the tightening controller are transferred
after this command is output.
Sent by: Tightening controller
Transfer of all existing tightening program or tightening application numbers of the tightening controller.
Note:
Supported OP variants and systems:
–Rexroth OP
CS351 compact system: Only program numbers 0 … 99 that are available are output.
Modular system 350: Only application numbers 0 … 47 or 99 that are actually available are output.
Rexroth OP-Ford
CS351 compact system and tightening channels (spindle 01 ...): Only program numbers 0 … 99 that are
available are output.
KE350 (spindle 00): Only application numbers 0 … 47 that are available are output.
Rexroth OP BMW
CS351 compact system and tightening channels (spindle 01 ...): Only program numbers 0 … 99 that are
available are output.
KE350 (spindle 00): Only application numbers 0 … 47 that are available are output.
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field:
Total data length = (1 + number of tightening programs/tightening application) x 3 bytes
Possible response: none
Table 6–81: MID 0011 revision 001
Parameter Comments Bytes
Tightening program/tightening
application number
The value consists of three ASCII characters.
ID -
Value range 000 999
Presetting -
Example:
Number of tightening
programs/tightening
applications
1
Value 001
3
Tightening program/tightening
application number
The value consists of three ASCII characters.
ID -
Value range 000 999
Presetting -
Example:
Tightening program/tightening
application number
2
Value 002
3
Data length revision 001 (with one tightening program/tightening application)
6