Example:
Using the values from the example above, the value of the data field for revision 001 would be as follows:
01C341212 02670919 032009-01-12:14:43:5704476547
053.14.4 06 07
Meanings of the individual values:
01C341212 Tool number
02670919 : cycles
2009-01-12:14:43:57 date of the last check
476547 : Serial number
053.14.4 Software version1
MID 0042 Deactivate tool
MID 0043 Activate tool
Sent by: superordinate computer
The tightening channel (CS) or tightening cell (modular system) can be blocked with this command.
Note:
In the PLC assignment table, the Enable signal must be applied to the OP module (see Chapter PLC signals from
the tightening controller from page 172). As regards the compact system, the Enable signal must be applied to bit
1.0 of the OP PLC module in the PLC assignment table. As regards applications on the KE, the FO 1 Disable signal
must be applied to bit 5.1 of the OP PLC module.
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
Command accepted 0005 -
Command error 0004 98 Request timeout in the control or PLC signal not
assigned in the PLC assignment table.
Sent by: superordinate computer
The tightening channel (CS) or tightening cell (modular system) can be released with this command.
Note:
In the PLC assignment table, the Enable signal must be applied to the OP module (see Chapter PLC signals from
the tightening controller from page 172). As regards the compact system, the Enable signal must be applied to bit
1.0 of the OP PLC module in the PLC assignment table. As regards applications on the KE, the FO 1 Disable signal
must be applied to bit 5.1 of the OP PLC module.
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
Command accepted 0005 -
Command error 0004 98 Request timeout in the control or PLC signal not
assigned in the PLC assignment table