388/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
Tightening status – Rexroth OP/Rexroth OP-BMW:
–0: NOK
–1: OK
Exception if MID61/MID65 evaluation and batch information from
application result is selected in the configuration for Open Protocol:
In application operation, the evaluation of the application for the
tightening status is applied.
– Rexroth OP-Ford:
–0: NOK
–1: OK
– 2: Loosen
– 3: Quality code “Start-up test”
– 4: Quality code “(C)CW = 0”
– 5: Quality code “TorqL”
The setting MID61/MID65 evaluation and batch information from
application result in the configuration for Open Protocol has no
effect.
The value consists of one ASCII character.
ID -
-
Value range 0–5
Presetting -
Example:
Tightening status OK
Value 0
1
Torque status – 0: Low
–1: OK
–2: High
The value consists of one ASCII character.
ID -
Value range 0–2
Presetting -
Example:
Torque status High
Value 2
1
Angle status – 0: Low
–1: OK
–2: High
The value consists of one ASCII character.
ID -
Value range 0–2
Presetting -
Example:
Angle status OK
Value 1
1
Torque (T) The value is multiplied by 100 and transferred as a whole number
(rounded to 2 decimals).
The value consists of six ASCII characters.
ID -
Value range 000000 – 999999
Presetting -
Example:
Torque (T) 20,00
Value 002000
6
Table 6–103: MID 0061 revision 999
Parameter Comments Bytes