3 608 878 300 Tightening Technology | Bosch Rexroth AG 387/641
System 350 | 3 608 878 300/2019-03
OK counter limit Start as a single channel (SE/CS): Presetting of the OK counter set
value
KE application start: Default value is 0
Rexroth OP/Rexroth OP-BMW: Exception if MID61/MID65
evaluation and batch information from application result is
selected in the configuration for Open Protocol: If the application is
parameterized from the job with a counter, the set value of the OK
counter is returned.
The value consists of four ASCII characters.
ID -
Value range 0000 9999
Presetting No presetting for single channels
Fixed value 0001 when starting in an application
Example:
OK counter limit 12
Value 0012
4
OK counter value Start as a single channel (SE/CS): Actual value of the OK counter
KE application start: Default value is 0
Rexroth OP/Rexroth OP-BMW: Exception if MID61/MID65
evaluation and batch information from application result is
selected in the configuration for Open Protocol: If the application is
parameterized from the job with a counter, the actual value of the OK
counter is returned.
The value consists of four ASCII characters.
ID -
Value range 0000 9999
Presetting No presetting for single channels
Fixed value 0001 when starting in an application
Example:
OK counter value 4
Value 0004
4
OK/NOK counter status Status of the OK/NOK counter.
0: if not 1 or 2
1: Ch x.y CntOK = 1
2: OK/NOK counter not used (not configured)
Rexroth OP/Rexroth OP-BMW: Exception if MID61/MID65 evaluation
and batch information from application result is selected in the
configuration for Open Protocol: In application operation, the OK/NOK
counter of the application is applied (parameterized from the job).
The value consists of one ASCII character.
ID -
Value range 0–2
Presetting -
Example:
OK/NOK counter
status
OK/NOK counter not used
Value 2
1
Table 6–103: MID 0061 revision 999
Parameter Comments Bytes